On 10/10/14 7:36 AM, Kester Wong wrote:
Hi Mark,


I think it was due to the charged groups in  my temp. coupling setting; I had
the H3O cation(s) and Cl anion(s) grouped separately:

tc-grps                  = GRA SOL H3O Cl-

; Time constant (ps) and reference temperature (K)

tau-t                    = 0.5 0.5 0.5 0.5

ref-t                    = 300 300 300 300


Calculations run fine once I grouped the ions together, or water+ions.


You shouldn't couple ions separately from the solvent; that's just not stable.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 601
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==================================================
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to