On 5/10/15 3:28 PM, sanjay choubey wrote:
HI,    I am running membrane protein dynamics. After energy minimization i am 
getting the following error. I am not getting how to rectify it.    Energy is 
minimized in fewer steps. Without proper minimization i cant proceed to next step 
of NVT run. Here is the error:  Steepest Descents:   Tolerance (Fmax)   =  
1.00000e+03   Number of steps    =        50000Step=   14, Dmax= 1.2e-06 nm, Epot= 
 3.71240e+18 Fmax=         inf, atom= 842Stepsize too small, or no change in 
energy.Converged to machine precision,but not to the requested precision Fmax < 
1000
Double precision normally gives you higher accuracy.You might need to increase 
your constraint accuracy, or turnoff constraints alltogether (set constraints = 
none in mdp file)
writing lowest energy coordinates.
Steepest Descents converged to machine precision in 15 steps,but did not reach the 
requested Fmax < 1000.Potential Energy  =  3.7124040e+18Maximum force     =     
       inf on atom 842Norm of force     =            inf


Infinite force suggests a catastrophically bad starting configuration.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 629
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==================================================
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to