On 6/1/15 9:07 AM, soumadwip ghosh wrote:
Hi Justin,
             the snapshot I uploaded in the URL is of the SSDNA-CNT
system after energy minimization step not before it. I stripped off
water and ions from the system for the ease of visualization. I would
be grateful if you suggest me a possible way out.


I don't see how that changes what I've said. You have a topology problem with the CNT. Simplify the system - build a smaller CNT, minimize it in vacuo, etc, then make it bigger/more complex. Look at the atoms that are distorting and check the existence of their bonded interactions and associated parameters.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 629
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==================================================
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to