Dear users,

I am trying to get the conformational entropy of some structures but the
results I got are strange. I tried two methods. I removed jumps from
trajectory and centered the protein in box (1).  I used the raw trajectory
(2). GROMACS gives different results for each processes. Which trajectory
should I use for the conformational entropy?


For instance:

1) trajectory without jumps

gmx trjconv -f md.xtc -s md.tpr -o traj-nojump.xtc -pbc nojump -b 30000

gmx trjconv -f traj-nojump.xtc -s md.tpr -o traj-centered.xtc -pbc mol -ur
compact -center

gmx covar -f traj-centered.xtc -s md.tpr -b 30000

gmx anaeig -f eigenvec.trr -entropy

The Entropy due to the Quasi Harmonic approximation is 49621.05 J/mol K (I
think this value is not physical)


2) raw trajectory

gmx covar -f md.xtc -s md.tpr -b 30000

gmx anaeig -f eigenvec.trr -entropy

The Entropy due to the Quasi Harmonic approximation is 2633.88 J/mol K


I did some tests on GROMACS 5.0.4 and GROMACS 5.0.6.


-- 
Ahmet Yıldırım
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.