On 3/25/16 8:03 PM, Soumya Lipsa Rath wrote:
Dear Justin and Nikhil,

Many thanks for your suggestions. Justin, I had optimized the parameters
using VMD's FFTK toolkit, so I just replaced my results in the *.str file
obtained from paramchem.

I tried minimizing the ligand in vaccum and in a solvent box, in both
cases, the molecule just scatters apart (pardon me, the bond doesn't
break).

I think there might be something wrong with the topology. However, I just
followed the general steps.


Well, when relying on automated methods fails, you have to roll your sleeves up and do the work yourself :)

If you can provide the stream file and coordinates of the ligand, I will try to offer suggestions; if you can share them publicly across the list it may be informative for others to listen in on the conversation.

Note, though, that the CGenFF paper is itself a tutorial on how to parametrize small molecules, and there are even more detailed CGenFF tutorials available online (check our website).

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 629
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==================================================
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to