On 6/16/17 7:14 AM, Quyen V. Vu wrote:
Dear GMX developer,
I don't know this mailing list is suitable for posting issue or not, if
not- forgive me.

I want to report about gmx genion module

If i want to add concentration of salt by -conc option, it just correct for
monovalent salt (eg. NACL).

For multivalent salt(MGCL2), if I use -pname MG -nname CL -conc X -neutral
, it wil treat MG as monovanlent cation and give the wrong number of ions
add into my system, so  I have to use -np and -nn option to get correct the
number of ions.


If you set the correct value of -pq then you'll get the right result. genion defaults to assuming everything is monovalent and if that's not the case, you have to provide correct instructions via the command line.

-Justin

--
==================================================