Hi Experts,
I am doing simulation for permeability calculation. 
 In my simulation, water molecule is constrained (inside the Bilayer) at fixed 
distance from centre of the Bilayer. And another constrained in bulk water. I 
am doing equilibration with V-rescale(thermostat) and berendsen(for barostat) 
for 5ns and then production run with Nose-Hoover and parrinello-Rahman for 
15ns. Simulation is crashing during production run after few nanoseconds run. 
Sometimes I get error "distance between pull group 1(Bilayer COM) and 3(water) 
is large than 0.49 times the box size. You might want to consider using 
'pull-geometry =direction-periodic' instead "
 But I cannot use direction-periodic in NPT. 
 Sometimes I get error, "water molecule starting at atom XXX can not be 
settled."
  I observed, these XXX water molecules are not constrained one's  but they are 
from bulk water surrounding Bilayer. 
Question:
 1. What is alternative for "pull-geometry=distance" if my constrained molecule 
going outside the box due to volume fluctuations, since we cannot use 
direction-periodic in NPT.
 Molecule is constrained around 1nm inside the initial box boundary.
 2. What might be the reason for instability in bulk water which is SPC. 
 3. If there is distortions in Bilayer during pulling, leading to overlap, 
simulation would have crashed in initial stages, why it is crashing in later 
stages. 

 Any helpful tips, suggestions will be much appreciated.

Yogesh

Yogesh
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to