On 9/6/17 5:36 AM, Seera Suryanarayana wrote:
Dear gromacs users,

I have gone through one gromacs tutorial of md simulation in solvent. Where
they mentioned that successive removal of position restrain. In other words
first they have done NPT ensemble with 1000  1000  1000 energy constants,
then re executed the NPT ensemble with 100   100   100 energy constants and
finally third time they ran the NPT ensemble with 10   10   10 energy
constants. After this run they have stated the real MD production run with
position restraint. But I have done NPT ensemble only with 1000  1000 1000
force constant and then I removed the complete position restrains before MD
production run. My question comes here, Is there any difference between
their methodology and my methodology?


Well, naturally there is a difference, but whether or not it matters is a different question :)

I have never done step-wise removal of position restraints. Some people swear by it. Same story with warming a system from 0 K to a target temperature - I see no benefit but others believe it's necessary. The purpose of equilibration is to relax the system and achieve a reasonably stable thermodynamic ensemble. If you've done that, proceed with your simulation.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

[email protected] | (540) 231-3129
http://www.biochem.vt.edu/people/faculty/JustinLemkul.html

==================================================
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to [email protected].

Reply via email to