Hi,

I tried using the regular PME method with and without corrections. The
results don't depend on the choice of ewald-geometry  at all!

I used (Gromacs 5.1):
wall-ewald-zfac = 3
ewald-geometry = 3d     ; This prompts a warning because I am using 2 walls
- 2d system. I forced this with maxwarn.
E-z                    = 1 5 0

and I also used
wall-ewald-zfac = 3
ewald-geometry = 3dc   ; No warnings since this is recommended
E-z                    = 1 5 0

I checked that this input was being processing correctly on topol.tpr. For
the first case, I see ewald-geometry = 0 and the second case ewald-geometry
= 1.

The electric field from ionic liquid has a magnitude of ~7.5 V/nm in the
opposite direction to the applied electric field for both cases. This is
greater than the applied 5. I obtained the electric field using gmx
potential.

I would very much appreciate any recommendations.

Dan

<http://www.avg.com/email-signature?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>
Virus-free.
www.avg.com
<http://www.avg.com/email-signature?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>
<#m_-5936464299898835406_DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2>

On Mon, Nov 13, 2017 at 10:22 AM, Dan Gil <dan.gil9...@gmail.com> wrote:

> Hi,
>
> I am using gmx potential to measure the electric field. I've reported the
> values from field.xvg in my previous email. The field at the edges of the
> ionic liquid near the walls will oscillate because of the electric double
> layer but it is the bulk field I am concerned with.
>
> I read the supporting information - I thought that the Ewald summation
> correction for 2 dimensions was supposed to cancel out interactions between
> periodic images in the z direction?
>
> Were you using the regular 3-D Ewald summation in this work? I might try
> carrying out the calculations that way.
>
> Dan
>
> On Mon, Nov 13, 2017 at 2:23 AM, David van der Spoel <sp...@xray.bmc.uu.se
> > wrote:
>
>> On 11/11/17 16:44, Dan Gil wrote:
>>
>>> Hi,
>>>
>>> Just wanted to see if anyone had any thoughts...
>>>
>>> For more information, if I use:
>>> wall-ewald-zfac = 3
>>> E-z                    = 1 5 0
>>> The electric field from ionic liquid has a magnitude of 7.5 V/nm in the
>>> opposite direction to the applied electric field. This makes no sense to
>>> me
>>> at all.
>>>
>>> With
>>> wall-ewald-zfac = 5
>>> E-z                    = 1 5 0
>>> The ionic liquid E is -6.2
>>>
>> How do you measure the electric field? Using gmx potential?
>> What numbers does the (optional?) file field.xvg contain?
>>
>> There can of course be a difference between applied field and effective
>> field, in particular with PBC. I sugges you read the supporting information
>> for our paper: Carl Caleman and David van der Spoel: Picosecond Melting of
>> Ice by an Infrared Laser Pulse - A Simulation Study Angew. Chem. Intl. Ed.
>> 47 pp. 1417-1420 (2008)
>>
>>>
>>> With
>>> wall-ewald-zfac = 10
>>> E-z                    = 1 5 0
>>> The electric field is still slightly above the expected 5 V/nm.
>>>
>>> The dimensions of the box is about 5x5x20 nm3.
>>>
>>> Reading various sources say that the wall factor should not matter as
>>> long
>>> as it is sufficiently large (x3) but in my case it seems to matter a lot.
>>> Should I report this as a bug or do you think I can investigate this
>>> further?
>>>
>>> Best Regards,
>>>
>>> Dan
>>>
>>> <http://www.avg.com/email-signature?utm_medium=email&utm_sou
>>> rce=link&utm_campaign=sig-email&utm_content=webmail>
>>> Virus-free.
>>> www.avg.com
>>> <http://www.avg.com/email-signature?utm_medium=email&utm_sou
>>> rce=link&utm_campaign=sig-email&utm_content=webmail>
>>> <#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2>
>>>
>>>
>>> On Wed, Nov 8, 2017 at 11:37 AM, Dan Gil <dan.gil9...@gmail.com> wrote:
>>>
>>> Hello,
>>>>
>>>> I am studying room-temperature ionic liquids in slab geometry and I am
>>>> experiencing that I cannot get rid of the interactions between periodic
>>>> images in the z-direction. Is there something wrong with what I am
>>>> doing or
>>>> is this inevitable?
>>>>
>>>> The reason I think this is because when I change "wall-ewald-zfac" the
>>>> results change also.
>>>>
>>>> Gromacs 5.1
>>>> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
>>>> -
>>>> ;Integration Method and Parameters
>>>> integrator               = md
>>>> nsteps                   = 4000000
>>>> dt            = 0.002
>>>> nstenergy                = 100
>>>> nstcalcenergy            = 100
>>>> nstlog                   = 5000
>>>>
>>>> ;Output Control
>>>> nstxout = 100
>>>> nstvout = 10000000
>>>>
>>>> ;Cutoff Schemes
>>>> cutoff-scheme            = verlet
>>>> rlist                    = 1.0
>>>> vdw-type                 = cut-off
>>>> rvdw                     = 1.0
>>>> DispCorr                 = EnerPres
>>>>
>>>> ;Coulomb interactions
>>>> coulombtype              = pme
>>>> rcoulomb                 = 1.0
>>>> fourierspacing           = 0.4
>>>>
>>>> ;Constraints
>>>> constraints              = all-bonds
>>>>
>>>> ;Temperature coupling
>>>> gen-vel                  = yes
>>>> tcoupl                   = v-rescale
>>>> tc-grps                  = System
>>>> tau-t                    = 0
>>>> ref-t                    = 300
>>>>
>>>> ;Walls
>>>> pbc                      = xy
>>>> nwall                    = 2
>>>> wall-type                = 10-4
>>>> ewald-geometry           = 3dc
>>>> wall-atomtype            = cp cm
>>>> wall-density             = 5 5
>>>> wall-ewald-zfac          = 10
>>>>
>>>> ;Electric Field
>>>> ;Cosine with freq=0, Field V/nm, Phase=n/a
>>>> E-z                      = 1 0 0
>>>> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
>>>> -
>>>>
>>>> Best Regards,
>>>>
>>>> Dan
>>>>
>>>>
>>
>> --
>> David van der Spoel, Ph.D., Professor of Biology
>> Head of Department, Cell & Molecular Biology, Uppsala University.
>> Box 596, SE-75124 Uppsala, Sweden. Phone: +46184714205.
>> http://www.icm.uu.se
>> --
>> Gromacs Users mailing list
>>
>> * Please search the archive at http://www.gromacs.org/Support
>> /Mailing_Lists/GMX-Users_List before posting!
>>
>> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
>>
>> * For (un)subscribe requests visit
>> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
>> send a mail to gmx-users-requ...@gromacs.org.
>>
>
>
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to