Okay. Thanks Justin!
On 27.03.2018 21:12, Justin Lemkul wrote:
On 3/27/18 4:44 AM, Hermann, Johannes wrote:
Dear All, dear Justin,
I am playing around with my umbrella sampling setup and I was looking
at your paper which you linked in your umbrella sampling tutorial
("Assessing the Stability of Alzheimer’s Amyloid Protofibrils Using
Molecular Dynamics").
Up to a distance of 2nm you use a 0.1nm spacing, beyond a 0.2nm
spacing. Which harmonic force constant pull_coord1_k do you use for
the 0.1nm spacing? In comparison to the 0.2nm spacing, where
pull_coord1_k=1000.
Is there a general rule of thumb between window distance and force
constant? Or is it always try and error while checking the histograms?
You can set the value of k based on experimental methods or somewhat
ad hoc, but then yes, you have to check overlap. I don't know of any
useful way of trying to predict how the intermolecular forces in the
system will respond in such a way that you can exactly say a priori
how to set up the windows.
-Justin
--