Den 2018-08-14 kl. 16:07, skrev Pelin S Bulutoglu:
Dear GROMACS users,

I am working on simulating a glycine crystal using GAFF force field with CNDO 
point charges in an NPT ensemble. I want to calculate the enthalpy and Cp of 
the crystal. However, the list that comes up following gmx energy command does 
not include the enthalpy or PV options, as it would normally do for NPT 
simulations. Does this mean that the simulation does not exhibit NPT behavior? 
I believe that this is not the case, since upon inspection of the temperature 
and pressure values, I found that they are both constant (within statistical 
error) throughout the simulation. What may be the cause of this? The following 
are some of my input parameters:

    cutoff-scheme                  = Verlet
    nstlist                        = 40
    ns-type                        = Grid
    pbc                            = xyz
    verlet-buffer-tolerance        = 0.005
    rlist                          = 1.4
    coulombtype                    = PME
    coulomb-modifier               = Potential-shift
    rcoulomb-switch                = 0
    rcoulomb                       = 1.4
    rvdw                           = 1.4
    DispCorr                       = EnerPres
    table-extension                = 1
    fourierspacing                 = 0.12
    pme-order                      = 4
    tcoupl                         = V-rescale
    nsttcouple                     = 10
    pcoupl                         = Berendsen
    pcoupltype                     = Anisotropic
    nstpcouple                     = 10
    tau-p                          = 2
    compressibility (3x3):
       compressibility[    0]={ 4.50000e-05,  4.50000e-05,  4.50000e-05}
       compressibility[    1]={ 4.50000e-05,  4.50000e-05,  4.50000e-05}
       compressibility[    2]={ 4.50000e-05,  4.50000e-05,  4.50000e-05}
    ref-p (3x3):
       ref-p[    0]={ 1.00000e+00,  1.00000e+00,  1.00000e+00}
       ref-p[    1]={ 1.00000e+00,  1.00000e+00,  1.00000e+00}
       ref-p[    2]={ 1.00000e+00,  1.00000e+00,  1.00000e+00}
    refcoord-scaling               = COM

Any input would be greatly appreciated. Thanks in advance.

Pelin Su Bulutoglu

The enthalpy should be there with any modern gromacs version if you are using constant pressure simulations. Please double check gmx energy options. Cp is more tricky because you need quantum corrections.

--
David van der Spoel, Ph.D., Professor of Biology
Head of Department, Cell & Molecular Biology, Uppsala University.
Box 596, SE-75124 Uppsala, Sweden. Phone: +46184714205.
http://www.icm.uu.se
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.