I figure it might be helpful to see my other files so I include a link:
https://github.com/SpaceDucK77/StringMethodMaster/tree/master/Prototypes/P3_Pull_coordinates/manual_test_justin


With Regards
Marko Petrovic
Educator
Computational Science and Technology
School of Electrical Engineering and Computer Science
KTH Royal Institute of Technology

On 5 Apr 2020, at 23:09, Justin Lemkul 
<jalem...@vt.edu<mailto:jalem...@vt.edu>> wrote:



On 4/5/20 5:05 PM, Marko Petrovic wrote:
Hello.

I've been trying to do coordinate pulling of dihedral angles of an alanine 
dipeptide in vacuum and used the umbrella sampling tutorial as a starting 
point. I'm trying to generate initial configurations for later runs, but the 
mdrun ends in a segmentation fault with error messages like:

Step 15707, time 31.414 (ps)  LINCS WARNING
relative constraint deviation after LINCS:
rms 0.025328, max 0.098100 (between atoms 11 and 13)
bonds that rotated more than 30 degrees:
 atom 1 atom 2  angle  previous, current, constraint length
      7      8   90.4    0.1006   0.1054      0.0997
     11     13   90.2    0.1110   0.1220      0.1111

Step 15708, time 31.416 (ps)  LINCS WARNING
relative constraint deviation after LINCS:
rms 52572448.000000, max 238546496.000000 (between atoms 7 and 8)
bonds that rotated more than 30 degrees:
 atom 1 atom 2  angle  previous, current, constraint length
      7      8  109.3    0.1054 23783084.0000      0.0997
      9     11  119.5    0.1543 1995948.6250      0.1538
     11     12  162.6    0.1127 1995948.6250      0.1111
     11     13  115.6    0.1220 1995948.5000      0.1111
     11     14  112.7    0.1124 1995948.6250      0.1111
Wrote pdb files with previous and current coordinates
Segmentation fault: 11

Perhaps the seg fault is not related to the warnings at all but as I am not 
certain what they mean and do think they are enough to cause some problems 
anyway I would like to understand them in general and also know what columns 
previous and current are saying.

They refer to bond lengths, what the length was at the previous step and what 
it is now, compared to what the reference value should be. Your values indicate 
catastrophic distortion of the structure.

As the original tutorial was done for a water solution and mine is conducted in 
vacuum I am guessing my modifications to the .mdp files are not completely 
updated so any tips on that woul also be helpful.

There's no way to provide any useful advice without you posting your .mdp file. 
Note that the umbrella sampling tutorial has basically no relevance to anything 
you're doing because enforced dihedral rotation didn't exist when I wrote it :)

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Office: 301 Fralin Hall
Lab: 303 Engel Hall

Virginia Tech Department of Biochemistry
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu<mailto:jalem...@vt.edu> | (540) 231-3129
http://www.thelemkullab.com<http://www.thelemkullab.com/>

==================================================

--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org<mailto:gmx-users-requ...@gromacs.org>.

-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.