In GSAS-2 you refine size and strain for each phase instead. It makes sense since instrument parameters do not vary with phase!
On Wed, Aug 22, 2018 at 10:58 AM, Emily Siska <[email protected]> wrote: > In GSAS I when there was more than one phase you could refine GU GV, GW > and LX, LY for each > phase separately. Is that possible in GSAS II? If so how? > > Sorry if you have received this message multiple times - I have been > having trouble with the server. > > > Thank you for your help! > > Best Regards, > Emily Siska > > > -- > Emily Siska > > Chemistry Graduate Assistant > Chemistry/HiPSEC > > Science and Engineering Building, Room 2173 > University of Nevada, Las Vegas > 4505 S. Maryland Pkwy. > Las Vegas, NV 89154-4003 > Office: (702) 894-1478 > Cell: (818) 642-7718 > > _______________________________________________ > GSAS-II mailing list > [email protected] > https://mailman.aps.anl.gov/mailman/listinfo/gsas-ii > -- -- Sergey Ushakov PhD Staff Research Associate Peter A Rock Thermochemistry Laboratory and NEAT ORU Rm 4415, Chemistry Annex University of California, Davis Davis, CA 95616 phone (530) 902-8185
_______________________________________________ GSAS-II mailing list [email protected] https://mailman.aps.anl.gov/mailman/listinfo/gsas-ii