Hi,

> 1. http://www.h2database.com/html/advanced.html#mvcc :
> "If multiple connections concurrently try to update the same row, this
> database fails fast: a concurrent update exception is thrown."

This is no longer the case. I will change the documentation to: "If
multiple connections concurrently try to update the same row, the
database waits until it can apply the change, but at most until the
lock timeout expires.". I hope it is understandable...

> bug in docs?

A bug in the documentation.

> what is expected behavior?

The second connection should be able to update (you may need to change
the lock timeout).

Regards,
Thomas

--~--~---------~--~----~------------~-------~--~----~