Le 23/10/2019 à 19:31, William Dauchy a écrit :
if I'm not wrong, we never enter val_fc_time_value when an associated fetcher such as `fc_rtt` is called without argument. meaning `type == ARGT_STOP` will never be true and so the default `data.sint = TIME_UNIT_MS` will never be set. remove this part to avoid thinking default data.sint is set to ms while reading the code.
Hi William, You're right. I merged your patch. Thanks. -- Christopher Faulet