Hi - it's the same as in standard FIX usage - the file listing bad components is called hand_labels_noise.txt - inside the ICA output folder. Cheers
> On 9 Mar 2016, at 03:25, Ely, Benjamin <benjamin....@mssm.edu> wrote: > > Hi all, > > I’m interested in running some analyses (particularly smoothness estimations) > on the noise components identified by ICA-FIX. I’ve looked through several > subjects’ ICA folders (e.g., > rfMRI_REST1_LR_hp2000.ica/filtered_func_data.ica/), which contain a number of > output stats and nifti files, but I can’t find an indication of which > components were classified as “good” and “bad”. Is this information available? > > Thanks! > -Ely > _______________________________________________ > HCP-Users mailing list > HCP-Users@humanconnectome.org > http://lists.humanconnectome.org/mailman/listinfo/hcp-users --------------------------------------------------------------------------- Stephen M. Smith, Professor of Biomedical Engineering Head of Analysis, Oxford University FMRIB Centre FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK +44 (0) 1865 222726 (fax 222717) st...@fmrib.ox.ac.uk http://www.fmrib.ox.ac.uk/~steve --------------------------------------------------------------------------- Stop the cultural destruction of Tibet _______________________________________________ HCP-Users mailing list HCP-Users@humanconnectome.org http://lists.humanconnectome.org/mailman/listinfo/hcp-users