On Sunday 14 October 2007, Karel Kulhavy wrote:
> What does the Operating Point Analysis (op) take for the DC
> value if a time-dependent function (for example pwl) is
> specified in current or voltage source? Is it zero? Or the
> value of the function in time point zero?

It takes the value at time point zero.

If you want it to be zero, say "DC 0".

It is supposed to be Spice compatible.


You didn't ask, but the AC analysis takes the operating point 
from the most recent DC, OP, or tran point.  This differs from 
Spice, which always takes "op".