What antibody are you trying to use?

-----Original Message-----
From: histonet-boun...@lists.utsouthwestern.edu 
[mailto:histonet-boun...@lists.utsouthwestern.edu] On Behalf Of 
histonet-requ...@lists.utsouthwestern.edu
Sent: Sunday, August 01, 2010 12:01 PM
To: histonet@lists.utsouthwestern.edu
Subject: Histonet Digest, Vol 81, Issue 1

Send Histonet mailing list submissions to
        histonet@lists.utsouthwestern.edu

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.utsouthwestern.edu/mailman/listinfo/histonet
or, via email, send a message with subject or body 'help' to
        histonet-requ...@lists.utsouthwestern.edu

You can reach the person managing the list at
        histonet-ow...@lists.utsouthwestern.edu

When replying, please edit your Subject line so it is more specific than "Re: 
Contents of Histonet digest..."


Today's Topics:

   1. Help with Biocare polymer detection kit!! (Jennifer Campbell)


----------------------------------------------------------------------

Message: 1
Date: Sat, 31 Jul 2010 12:03:39 -0700
From: "Jennifer Campbell" <jcampb...@vdxpathology.com>
Subject: [Histonet] Help with Biocare polymer detection kit!!
To: <histonet@lists.utsouthwestern.edu>
Message-ID:
        <5658cbdb9eae6545abe50d2563d81bf8181...@vdxserver01.vdxpathology.local>
        
Content-Type: text/plain;       charset="iso-8859-1"

I have been trying to get the Mach 1 polymer kit from Biocare to work on my K9 
and feline tissue and I am getting terrible nonspecific staining in my positive 
and negative controls.  It appears to be sticking to something in the glands of 
the intestinal epithelia.  I am also getting nonspecific staining in my LN 
tissue.
I decided to switch over to polymer detection kit because I had been dealing 
with the issue of endogenous biotin when using the streptavidin biotin-based 
detection system, and now I am getting this other nonspecific staining!
I have tried doing runs eliminating my protein block and eliminating the 
negative control and primary antibody step altogether (to see if maybe the 
protein block or the diluent used in my negative control and antibody dilutions 
are causing the problem).  I have also reduced the incubation time of both the 
probe and polymer from 15 min and 30 min, respectively, to 10 min each.  I have 
tried cutting down my antigen retrieval time substantially as well.
 
I'm not sure what else could be causing this.  Any suggestions??
 
Thanks in advance,
 
Jennifer Campbell


------------------------------

_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu