On 20 Jul 2019 20:07, Ted Lemon <mel...@fugue.com> wrote:
On Jul 20, 2019, at 9:49 AM, RayH <v6...@globis.net> wrote:
Yes.

We decided to get some implementation experience before proceeding, and it hasn’t popped to the top of the stack yet (except maybe at this hackathon).

Thanks. Fair enough.

One question on re-reading this version: why not populate the reserve zone automatically from the data used to update the forward zone?

It's exactly the same set of servers, and it saves lots of additional work by the hosts.

If a host really wants a unique forward/reverse binding for a specific service, it can defend a unique stable gua address (rfc8064) for this purpose.

Regards,
_______________________________________________
homenet mailing list
homenet@ietf.org
https://www.ietf.org/mailman/listinfo/homenet