Hi Samuel!

On Fri, 15 Feb 2013, Samuel Groß wrote:
> 0x6020 - happens when the small button on the screen above the power
> button is pressed (toggles screen auto rotation under windows)

I'd have to add special handling for this.

> 0x60b0 and
> 0x60b1 - both show up in the logs regularily, I'm not sure what
> causes those...

There are two conditions that cause 60b0 and 60b1 events, check whether
they're related to IO ports or docks being plugged/unplugged...

Unfortunately, they're hooked directly to ACPI GPEs (interrupts) and GPIO
lines, so we need to actually find out the hard way what triggers them.

-- 
  "One disk to rule them all, One disk to find them. One disk to bring
  them all and in the darkness grind them. In the Land of Redmond
  where the shadows lie." -- The Silicon Valley Tarot
  Henrique Holschuh

------------------------------------------------------------------------------