I understood!

It sometimes occurs when pressing keys <Fn> + <F5> or <Fn> + <F6> for 
management of monitor brightness

-- 
Regars,
    Evgeny



Thu, 06 Nov 2014 10:23:19 +0300 от Евгений shur <eshur2...@mail.ru>:
>
>
>Hi! 
>
>In /var/llog/messages
>...
>Nov  6 09:37:54 thinkpad-1-home kernel: thinkpad_acpi: THERMAL ALERT: unknown 
>thermal alarm received
>Nov  6 09:37:54 thinkpad-1-home kernel: thinkpad_acpi: unhandled HKEY event 
>0x6060
>Nov  6 09:37:54 thinkpad-1-home kernel: thinkpad_acpi: please report the 
>conditions when this event happened to ibm-acpi-devel@lists.sourceforge.net
>...
>Nov  6 09:37:55 thinkpad-1-home kernel: thinkpad_acpi: THERMAL ALERT: unknown 
>thermal alarm received
>Nov  6 09:37:55 thinkpad-1-home kernel: thinkpad_acpi: unhandled HKEY event 
>0x6060
>Nov  6 09:37:55 thinkpad-1-home kernel: thinkpad_acpi: please report the 
>conditions when this event happened to ibm-acpi-devel@lists.sourceforge.net
>...
>
>dmesg in an investment.
>
>
> smart hdd
>
>smartctl -a /dev/sda
>smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-504.el6.x86_64] (local 
>build)
>Copyright (C) 2002-12 by Bruce Allen,  http://smartmontools.sourceforge.net    
>    
>
>=== START OF INFORMATION SECTION ===
>Device Model:     Crucial_CT960M500SSD1
>Serial Number:    1338094ECC66         
>LU WWN Device Id: 5 00a075 1094ecc66   
>Firmware Version: MU02                 
>User Capacity:    960 197 124 096 bytes [960 GB]
>Sector Sizes:     512 bytes logical, 4096 bytes physical
>Device is:        Not in smartctl database [for details use: -P showall]
>ATA Version is:   8                                                     
>ATA Standard is:  ATA-8-ACS revision 6                                  
>Local Time is:    Thu Nov  6 10:16:02 2014 MSK                          
>SMART support is: Available - device has SMART capability.              
>SMART support is: Enabled                                               
>
>=== START OF READ SMART DATA SECTION ===
>SMART overall-health self-assessment test result: PASSED
>
>General SMART Values:
>Offline data collection status:  (0x80) Offline data collection activity
>                                        was never started.              
>                                        Auto Offline Data Collection: Enabled.
>Self-test execution status:      (   0) The previous self-test routine 
>completed
>                                        without error or no self-test has ever 
> 
>                                        been run.                              
> 
>Total time to complete Offline                                                 
> 
>data collection:                ( 4470) seconds.                               
> 
>Offline data collection                                                        
> 
>capabilities:                    (0x7b) SMART execute Offline immediate.       
> 
>                                        Auto Offline data collection on/off 
>support.
>                                        Suspend Offline collection upon new    
>     
>                                        command.                               
>     
>                                        Offline surface scan supported.        
>     
>                                        Self-test supported.                   
>     
>                                        Conveyance Self-test supported.        
>     
>                                        Selective Self-test supported.         
>     
>SMART capabilities:            (0x0003) Saves SMART data before entering       
>     
>                                        power-saving mode.                     
>     
>                                        Supports SMART auto save timer.        
>     
>Error logging capability:        (0x01) Error logging supported.               
>     
>                                        General Purpose Logging supported.     
>     
>Short self-test routine                                                        
>     
>recommended polling time:        (   2) minutes.                               
>     
>Extended self-test routine                                                     
>     
>recommended polling time:        (  74) minutes.                               
>     
>Conveyance self-test routine                                                   
>     
>recommended polling time:        (   3) minutes.                               
>     
>SCT capabilities:              (0x0035) SCT Status supported.                  
>     
>                                        SCT Feature Control supported.         
>     
>                                        SCT Data Table supported.              
>     
>
>SMART Attributes Data Structure revision number: 16
>Vendor Specific SMART Attributes with Thresholds:  
>ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
>WHEN_FAILED RAW_VALUE
>  1 Raw_Read_Error_Rate     0x0032   100   100   ---    Old_age   Always       
>-       0        
>  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       
>-       0        
>  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       
>-       3478     
> 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       
>-       74       
>170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       
>-       18       
>171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       
>-       0        
>172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       
>-       0        
>173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       
>-       1        
>174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       
>-       29       
>181 Program_Fail_Cnt_Total  0x0022   100   100   ---    Old_age   Always       
>-       3199786025164
>183 Runtime_Bad_Block       0x0032   100   100   ---    Old_age   Always       
>-       0            
>184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       
>-       0
>187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       
>-       0
>188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       
>-       113
>194 Temperature_Celsius     0x0022   057   049   ---    Old_age   Always       
>-       43 (0 51 255 232 0)
>195 Hardware_ECC_Recovered  0x003a   100   100   ---    Old_age   Always       
>-       4294967295
>196 Reallocated_Event_Count 0x0032   100   100   ---    Old_age   Always       
>-       18
>197 Current_Pending_Sector  0x0032   100   100   ---    Old_age   Always       
>-       0
>198 Offline_Uncorrectable   0x0030   100   100   ---    Old_age   Offline      
>-       0
>199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       
>-       0
>202 Data_Address_Mark_Errs  0x0031   100   100   ---    Pre-fail  Offline      
>-       0
>206 Flying_Height           0x000e   100   100   ---    Old_age   Always       
>-       0
>
>SMART Error Log Version: 1
>No Errors Logged
>
>SMART Self-test log structure revision number 1
>Num  Test_Description    Status                  Remaining  LifeTime(hours)  
>LBA_of_first_error
># 1  Vendor (0xff)       Completed without error       00%      3451         -
># 2  Vendor (0xff)       Completed without error       00%      3169         -
># 3  Vendor (0xff)       Completed without error       00%      3159         -
># 4  Vendor (0xff)       Completed without error       00%      3145         -
># 5  Vendor (0xff)       Completed without error       00%      3138         -
># 6  Vendor (0xff)       Completed without error       00%      3124         -
># 7  Vendor (0xff)       Completed without error       00%      3110         -
># 8  Vendor (0xff)       Completed without error       00%      3096         -
># 9  Vendor (0xff)       Completed without error       00%      3082         -
>#10  Vendor (0xff)       Completed without error       00%      3068         -
>#11  Vendor (0xff)       Completed without error       00%      3054         -
>#12  Vendor (0xff)       Completed without error       00%      3040         -
>#13  Vendor (0xff)       Completed without error       00%      3026         -
>#14  Vendor (0xff)       Completed without error       00%      3011         -
>#15  Vendor (0xff)       Completed without error       00%      2997         -
>#16  Vendor (0xff)       Completed without error       00%      2983         -
>#17  Vendor (0xff)       Completed without error       00%      2969         -
>#18  Vendor (0xff)       Completed without error       00%      2954         -
>#19  Vendor (0xff)       Completed without error       00%      2939         -
>#20  Vendor (0xff)       Completed without error       00%      2925         -
>#21  Vendor (0xff)       Completed without error       00%      2909         -
>
>SMART Selective self-test log data structure revision number 1
> SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
>    1        0        0  Not_testing
>    2        0        0  Not_testing
>    3        0        0  Not_testing
>    4        0        0  Not_testing
>    5        0        0  Not_testing
>Selective self-test flags (0x0):
>  After scanning selected spans, do NOT read-scan remainder of disk.
>If Selective self-test is pending on power-up, resume after 0 minute delay.
>
>
>if it is necessary, it is ready to provide the demanded diagnostics
>
>-- 
>Regars,
>    Evgeny

------------------------------------------------------------------------------
Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server
from Actuate! Instantly Supercharge Your Business Reports and Dashboards
with Interactivity, Sharing, Native Excel Exports, App Integration & more
Get technology previously reserved for billion-dollar corporations, FREE
http://pubads.g.doubleclick.net/gampad/clk?id=157005751&iu=/4140/ostg.clktrk
_______________________________________________
ibm-acpi-devel mailing list
ibm-acpi-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/ibm-acpi-devel

Reply via email to