Vernooy, C.P. - SPLXM wrote:

Susan,

I think it is impossible:
A quick scan through data areas revealed several controlblocks that had 7
positions for the userid.
See:
Title: z/OS V1R3.0 TSO/E System Diagnosis: Data Areas
Document Number: GA22-7792-01

This limitation must be documented in TSO manuals.

Just to complete:
It is impossible to have 8-char userid under TSO.
It is possible to have 8-char userid for CICS, console, etc. Such user cannot logon to TSO and cannot be altered to logon - sometimes people like it.

Because of TSO restriction many shops don't use userid longer than 7.


--
Radoslaw Skorupka
Lodz, Poland

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html