Thanks all.

The $PXEQ and $SXEQ suggestions have sorted the problem of the residual state 
data in the WLM initiators.

The problem seems to have been caused because job(s) that abended were using 
PDSEs. This uses DIV apparently, and some control blocks got left behind in the 
initiator I guess. I'm also guessing that these control blocks have some kind 
of ACEE/SAF association, as that would explain why I could successfully run a 
job under the same userid as the one that abended, but unsuccssfully run one 
under a different userid.

Unfortunately I could not avail myself of IBM support on this problem because 
it's an OS/390 2.9 system (due for upgrade to z/OS 1.4 in July).

Thanks again all for the help and suggestions.