Guys,

You WANT VOLUME and UNIT parms so you can tailor the DDDEFs for your online and offline res target zones (please tell me you're doing that and not using renames to install).

Regards,
Tom Conley

----- Original Message ----- From: "Greg Shirey" <[EMAIL PROTECTED]>
Newsgroups: bit.listserv.ibm-main
Sent: Wednesday, August 24, 2005 2:10 PM
Subject: Re: VOLUME in SMP/E DDDEFs


We are in the process of installing CICS TS 2.3 and I can't find a single
DDDEF that has a value for either UNIT or VOLSER defined, but of course I
can't speak to IBM's packaging rules.

HTH,
Greg Shirey
Ben E. Keith Company


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED]
Behalf Of Patrick O'Keefe
Sent: Wednesday, August 24, 2005 10:35 AM

As part of an ESP I'm giving feedback on the product's SMP process.
I complained that UNIT and VOLUME weren't needed on DDDEFs if the datasets
were cataloged (and that their sample allocation job cataloged them).
I was told that IBM's product packaging rules require UNIT and VOLUME on
all DDDEFs.

Is that true?

<snip>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO