Hi, Thanks everyone. There was a syntax error in the IEASVC00 Member. I removed the last line with *** and IPLd. I am now able to do the INITRCON.
Thanks everyone who replied. Even the local IBM folks could not help. Special thanks to Lizette and Binyamin !! Regards, Srinivas G -----Original Message----- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Lizette Koehler Sent: Thursday, September 10, 2009 4:28 PM To: IBM-MAIN@bama.ua.edu Subject: Re: ABEND=SFCA during IMS10 installation ( Just a simple question. In SVC00 I am not sure, but should the SVC numbers be in order? I always have mine from 200 to 255 in sequence. Your display looks like they go in reverse order 255-200. What version of IMS are you running? What version of operating system? z/OS Vxxx And to clarify, when you scanned syslog you did not see the phrase SVC202 or IGC0020B or IGC0202 in any of the text? Lizette > Hi, > > I am getting the following error while Initrcon step(Initialize RECON / Register Data > Bases) of IMS IVP installation. This is the abend I get: > > ICH70001I IBMUSER LAST ACCESS AT 11:21:24 ON THURSDAY, SEPTEMBER 10, > 2009 > $HASP373 IV3F102J STARTED - INIT 1 - CLASS N - SYS MVS1 > IEA995I SYMPTOM DUMP OUTPUT 814 > SYSTEM COMPLETION CODE=FCA > TIME=11.57.15 SEQ=00054 CPU=0000 ASID=002C > PSW AT TIME OF ERROR 070C1000 818FBF4C ILC 2 INTC 0D > NO ACTIVE MODULE FOUND > NAME=UNKNOWN > DATA AT PSW 018FBF46 - 00181610 0A0D4110 016D182F > AR/GR 0: 8A2AA780/80000000 1: 00000000/80FCA000 > 2: 00000000/008CFBF0 3: 00000000/00FDCEC0 > 4: 00000000/008FF048 5: 00000000/008FDBC0 > 6: 00000000/818FBF26 7: 00000000/00FC4580 > 8: 00000000/00000000 9: 00000000/018FB920 > A: 00000000/008FDC80 B: 00000000/7F4E0090 > C: 00000000/0134A3B8 D: 00000000/0A816420 > E: 00000000/00FEC100 F: 01000002/00000000 > END OF SYMPTOM DUMP > IEF450I IV3F102J D INITRCON - ABEND=SFCA U0000 REASON=00000000 > $HASP395 IV3F102J ENDED > > > I am suspecting its related to SVC steps as part of IVP setup. > > I have run the SVS steps successfully: > IV3D209T Install TYPE 2 SVC > IV3D210T Link-edit TYPE 4 SVC > > My IEASVC00 is > SVCPARM 216,REPLACE,TYPE(3),EPNAME(DFHCSVC) /* CICS(CSVC) */ > SVCPARM 215,REPLACE,TYPE(6),EPNAME(DFHHPSVC) /* ONLY FOR HPO*/ > SVCPARM 203 REPLACE, /* IMS TYPE 2 SVC */ > TYPE(2) > SVCPARM 202 REPLACE, /* IMS TYPE 4 SVC FOR DBRC */ > TYPE(4) > **************************** BOTTOM OF DATA *************************** > > I have appended the SYS1.NUCLEUS with IMS1010.MLPALIB > > The CPAC.PARMLIB(IEALPA00) > INCLUDE LIBRARY(IMS1010.MLPALIB) VOLUME(Z11IM1) > MODULES(IGC0020B,DFSAFMD0) > > IGC203 is in SYS1.NUCLEUS dataset. > > What could I have done wrong? Any help is greatly appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html