Hi,

Thanks everyone. There was a syntax error in the IEASVC00 Member. I removed the 
last line with *** and IPLd.
I am now able to do the INITRCON.

Thanks everyone who replied. Even the local IBM folks could not help.

Special thanks to Lizette and Binyamin !!

Regards,
Srinivas G



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of 
Lizette Koehler
Sent: Thursday, September 10, 2009 4:28 PM
To: IBM-MAIN@bama.ua.edu
Subject: Re: ABEND=SFCA during IMS10 installation (

Just a simple question.  In SVC00 I am not sure, but should the SVC numbers
be in order?

I always have mine from 200 to 255 in sequence.  Your display looks like
they go in reverse order 255-200.

What version of IMS are you running? What version of operating system? z/OS
Vxxx

And to clarify, when you scanned syslog you did not see the phrase SVC202 or
IGC0020B or IGC0202 in any of the text?



Lizette


> Hi,
> 
> I am getting the following error while Initrcon step(Initialize RECON /
Register Data
> Bases) of IMS IVP installation. This is the abend I get:
> 
> ICH70001I IBMUSER  LAST ACCESS AT 11:21:24 ON THURSDAY, SEPTEMBER 10,
> 2009
> $HASP373 IV3F102J STARTED - INIT 1    - CLASS N - SYS MVS1
> IEA995I SYMPTOM DUMP OUTPUT  814
> SYSTEM COMPLETION CODE=FCA
>  TIME=11.57.15  SEQ=00054  CPU=0000  ASID=002C
>  PSW AT TIME OF ERROR  070C1000   818FBF4C  ILC 2  INTC 0D
>    NO ACTIVE MODULE FOUND
>    NAME=UNKNOWN
>    DATA AT PSW  018FBF46 - 00181610  0A0D4110  016D182F
>    AR/GR 0: 8A2AA780/80000000   1: 00000000/80FCA000
>          2: 00000000/008CFBF0   3: 00000000/00FDCEC0
>          4: 00000000/008FF048   5: 00000000/008FDBC0
>          6: 00000000/818FBF26   7: 00000000/00FC4580
>          8: 00000000/00000000   9: 00000000/018FB920
>          A: 00000000/008FDC80   B: 00000000/7F4E0090
>          C: 00000000/0134A3B8   D: 00000000/0A816420
>          E: 00000000/00FEC100   F: 01000002/00000000
>   END OF SYMPTOM DUMP
>  IEF450I IV3F102J D INITRCON - ABEND=SFCA U0000 REASON=00000000
>  $HASP395 IV3F102J ENDED
> 
> 
> I am suspecting its related to SVC steps as part of IVP setup.
> 
> I have run the SVS steps successfully:
> IV3D209T  Install TYPE 2 SVC
> IV3D210T  Link-edit TYPE 4 SVC
> 
> My IEASVC00 is
> SVCPARM 216,REPLACE,TYPE(3),EPNAME(DFHCSVC)         /* CICS(CSVC) */
> SVCPARM 215,REPLACE,TYPE(6),EPNAME(DFHHPSVC)      /*  ONLY FOR HPO*/
> SVCPARM 203 REPLACE,         /* IMS TYPE 2 SVC */
>             TYPE(2)
> SVCPARM 202 REPLACE,         /* IMS TYPE 4 SVC FOR DBRC */
>             TYPE(4)
> **************************** BOTTOM OF DATA ***************************
> 
> I have appended the SYS1.NUCLEUS with IMS1010.MLPALIB
> 
> The CPAC.PARMLIB(IEALPA00)
> INCLUDE LIBRARY(IMS1010.MLPALIB) VOLUME(Z11IM1)
>    MODULES(IGC0020B,DFSAFMD0)
> 
> IGC203 is in SYS1.NUCLEUS dataset.
> 
> What could I have done wrong? Any help is greatly appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to