Omit CUADD. 2009/10/13 Jeffrey Deaver <[email protected]>
> I have an IODF which has a mistake in it in regards to some new storage > we've attached... > > CNTLUNIT CUNUMBR=5000,PATH=((CSS(0),B3,B2,82,83,40,41,D0,D1)),* > UNITADD=((00,256)),CUADD=0,UNIT=2107 > IODEVICE ADDRESS=(5000,228),CUNUMBR=(5000),STADET=Y,UNIT=3390B > IODEVICE ADDRESS=(50E4,028),CUNUMBR=(5000),STADET=Y,UNIT=3390A > > The CUADD statements have the wrong value. They should be CUADD=50 etc > instead of CUADD=0 etc. > I altered the IODF and IPL'ed my test system, but the change has not taken. > In other words, I still can't access the storage.... > From an init job... > > ICK30713I UNABLE TO ALLOCATE UCB, RC=0008, RSN=0004 FROM IOSODS > ICK31024I UNABLE TO OPEN VOLUME. > ICK30003I FUNCTION TERMINATED. CONDITION CODE IS 12 > 12:26:00 10/13/09 > > I can't vary the paths online... > > IEE386I PATH(5001,40) NOT BROUGHT ONLINE > IEE763I NAME= IECVIOPM CODE= 0000000400000000 > IOS552I PATH NOT PHYSICALLY AVAILABLE > IEE764I END OF IEE386I RELATED MESSAGES > > Assuming I'm not missing some other configuration issue, I should be able > to change the IODF, IPL that LPAR and have the change take effect, right? > No POR necessary, right? > What am I missing? > Thanks. > > > Jeffrey Deaver, Engineer > Systems Engineering > [email protected] > 651-665-4231(v) > IS - "Creating competitive advantage with technology. Providing service > that excels." > OSS - " Where Innovation Happens" > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html