> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of David Booher
> 
> Hello,
> 
> Does anyone know a quick way around this?  Our z800 doesn't have a
crytographic processor, so ICSF
> isn't configured.
> 
>   RECEIVE SYSMODS
>           SOURCEID(PTF021)
>           FROMNETWORK(
>            SERVER(SERVINFO)
>        /*  CLIENT(CLNTINFO) */         /* <=== NOTE 4 */
>        /*  TRANSFERONLY  */            /* <=== NOTE 3 */
>                         ).
> 
> GIM23412S ** RECEIVE COMMAND PROCESSING HAS FAILED. ICSF IS NOT
AVAILABLE. DATA
>              PERFORMED ON PACKAGE U00745744.
> GIM20501I    RECEIVE PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE
WAS 12.

Depending on your release of SMP/E, you can code either:

//SMPJHOME DD  PATH='/usr/lpp/java/J6.0/'   <=== works with J1.4 or
later
//SMPCPATH DD  PATH='/usr/lpp/smp/classes/'

OR:

//CLNTINFO DD *                            
  <CLIENT                                  
    javahome="/usr/lpp/java/J6.0"  <=== works with J1.4 or later
    classpath="/usr/lpp/smp/classes">      
  </CLIENT>                                
/*  

and uncomment the CLIENT(CLNTINFO) line in //SMPCNTL.