Thanks again for your help. Roger -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Mark Zelden Sent: Tuesday, December 01, 2009 10:22 AM To: [email protected] Subject: Re: Jes2 Converter abend d37
Thanks. I thought it had something to do with in-stream proc processing. I have no idea if there is any way to control the converter allocation. I doubt it comes from the default in ALLOCxx. You would still have to open a PMR with IBM to find out unless someone on this list knows the definitive answer. Mark -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group - ZFUS G-ITO mailto:[email protected] z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html On Tue, 1 Dec 2009 09:08:11 -0500, Stock, Roger W <[email protected]> wrote: >Mark, > >VIO device type gen'd is 3390. >There was an in-stream proc that was executed once and most steps had >one or more DDs overridden. > >Roger > >-----Original Message----- >From: IBM Mainframe Discussion List [mailto:[email protected]] On >Behalf Of Mark Zelden >Sent: Monday, November 30, 2009 4:07 PM >To: [email protected] >Subject: Re: Jes2 Converter abend d37 > >Glad to hear. BTW, what device type is gen'd for VIO in your IODF? >And can you tell me if there was an in-stream PROC being executed? > >Mark >-- >Mark Zelden >Sr. Software and Systems Architect - z/OS Team Lead >Zurich North America / Farmers Insurance Group - ZFUS G-ITO >mailto:[email protected] >z/OS Systems Programming expert at >http://expertanswercenter.techtarget.com/ >Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html > >On Mon, 30 Nov 2009 15:54:32 -0500, Stock, Roger W <[email protected]> >wrote: > >>Success! >> >>That did it: removing some 2000+ comment lines allowed the job to >>submit. >> >>Thanks to all for your suggestions! >> >>Roger >> >>-----Original Message----- >>From: IBM Mainframe Discussion List [mailto:[email protected]] On >>Behalf Of Mark Zelden >>Sent: Monday, November 30, 2009 3:26 PM >>To: [email protected] >>Subject: Re: Jes2 Converter abend d37 >> >>Is that the message you get when ISPF temporary data sets for submit >>don't have enough space? I didn't think so. >> >>It sounds like you are using ISPF submit. The easiest way to get >around >>any space problems with ISPCTL0 is to use TSO SUBMIT instead: >> >>TSO SUBMIT 'data.set' or TSO SUBMIT 'PDS.DATA.SET(MEMBER)' >> >>But as I said, this doesn't look like an ISPCTL0 issue. If it was, I >>would >>expect the space abend on ISPCTL0, not a converter abend. >> >>BTW, ISPCTL0 is for edit/submit work. ISPCTL1-n is used by file >>tailoring >>IIRC (n = the logical screen number). >> >>Is there a PROC / instream proc in use? Can it be converted to just >>execute without a proc instead? Can you reduce the number of >statements >>(get rid of comments etc.) and try? Otherwise you may have to open >>a PMR with IBM. >> >>Mark >>-- >>Mark Zelden >>Sr. Software and Systems Architect - z/OS Team Lead >>Zurich North America / Farmers Insurance Group - ZFUS G-ITO >>mailto:[email protected] >>z/OS Systems Programming expert at >>http://expertanswercenter.techtarget.com/ >>Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html >> >> >> >>On Mon, 30 Nov 2009 15:12:13 -0500, Stock, Roger W <[email protected]> >>wrote: >> >>>I tried it but got the same error. >>>IEC031I D37-04,IFG0554P,JES2,JES2,SYS00010,VIO , >>>,SYS09334.T145558.RA000.JES2.R0400402 >>>IEF196I IEC031I D37-04,IFG0554P,JES2,JES2,SYS00010,VIO , , >>> >>>IEF196I SYS09334.T145558.RA000.JES2.R0400402 >>> >>>IEFC683I CONVERTER TERMINATED DUE TO SD37 ABEND REASON=00000004 >>> >>> >>>The ISPCTL0 DD was used for about 2,000+ I/Os. >>>All four DDs were allocated to temp files, but only the first had I/O. >>>The dataset SYS09334.T145558.RA000.JES2.R0400402 is the next temp file >>>after the ISPCTL3 (ISPCTL3 is .R0400401). >>> >>>Roger >>> >>> >>> >>>-----Original Message----- >>>From: IBM Mainframe Discussion List [mailto:[email protected]] On >>>Behalf Of Richbourg, Claude >>>Sent: Monday, November 30, 2009 2:44 PM >>>To: [email protected] >>>Subject: Re: Jes2 Converter abend d37 >>> >>>Put these in your TSO logon proc and you will be okay. >>> >>>//ISPCTL0 DD DISP=NEW,UNIT=VIO,SPACE=(CYL,(50,5)), >>>// DCB=(LRECL=80,BLKSIZE=800,RECFM=FB) >>>//ISPCTL1 DD DISP=NEW,UNIT=VIO,SPACE=(CYL,(50,5)), >>>// DCB=(LRECL=80,BLKSIZE=800,RECFM=FB) >>>//ISPCTL2 DD DISP=NEW,UNIT=VIO,SPACE=(CYL,(50,5)), >>>// DCB=(LRECL=80,BLKSIZE=800,RECFM=FB) >>>//ISPCTL3 DD DISP=NEW,UNIT=VIO,SPACE=(CYL,(50,5)), >>>// DCB=(LRECL=80,BLKSIZE=800,RECFM=FB) >>> >>>Thanks, >>>Claude >>> >>> >>> >>>-----Original Message----- >>>From: IBM Mainframe Discussion List [mailto:[email protected]] On >>>Behalf Of Stock, Roger W >>>Sent: Monday, November 30, 2009 2:29 PM >>>To: [email protected] >>>Subject: Jes2 Converter abend d37 >>> >>>Hi all, >>> >>>A vendor supplied me with a very large single job to install their >>>software (10,000+ lines). >>> >>>The jobs abends the JES2 converter: >>> IEC031I D37-04,IFG0554P,JES2,JES2,SYS00009,VIO , >>>,SYS09328.T110458.RA000.JES2.R0400331 >>> IEF196I IEC031I D37-04,IFG0554P,JES2,JES2,SYS00009,VIO , , >>> >>> IEF196I SYS09328.T110458.RA000.JES2.R0400331 >>> >>> IEFC683I CONVERTER TERMINATED DUE TO SD37 ABEND REASON=00000004 >>> >>> >>>How do I adjust JES2 to handle this job? >>>We are on zOS 1.9. >>> >>>Roger >>> >>> >>> > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [email protected] with the message: GET IBM-MAIN INFO >Search the archives at http://bama.ua.edu/archives/ibm-main.html > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [email protected] with the message: GET IBM-MAIN INFO >Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html