I can only relate my experinces I set
The ECB to SP 241 key 8
And it blew up withe above comp code
When I set SP241 to a ptr to sp 0 key 8 everything worked


Sent from my iPhone

On Dec 21, 2009, at 8:10 PM, David Alcock <mainframed...@sbcglobal.net> wrote:

The ECB storage has to have been obtained from the TCB
where the wait is taking place.

Like a couple of people have posted, this isn't true. One reason the poster may feel like this is true is if the ECB resides in storage obtained by a different task which has terminated (and storage obtained by that other task was freed). Many system ABEND codes start off as S0C4s.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html