I can only relate my experinces I set
The ECB to SP 241 key 8
And it blew up withe above comp code
When I set SP241 to a ptr to sp 0 key 8 everything worked
Sent from my iPhone
On Dec 21, 2009, at 8:10 PM, David Alcock
<mainframed...@sbcglobal.net> wrote:
The ECB storage has to have been obtained from the TCB
where the wait is taking place.
Like a couple of people have posted, this isn't true. One reason
the poster may feel like this is true is if the ECB resides in
storage obtained by a different task which has terminated (and
storage obtained by that other task was freed). Many system ABEND
codes start off as S0C4s.
----------------------------------------------------------------------