Does anyone have an electronic version of that 3390 reference card or know 
where I can download one?

Luke

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of 
Pommier, Rex R.
Sent: Monday, February 08, 2010 10:51 AM
To: [email protected]
Subject: Re: SMS error message IGD17051I. Why?

Bob,

Based on my trusty old 3390 reference card, the 182 byte block size will
only hold about 584 MB in 64K tracks.  If you were to crank your block
size up drastically, you would have plenty of room.

Rex

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Lester, Bob
Sent: Monday, February 08, 2010 10:32 AM
To: [email protected]
Subject: SMS error message IGD17051I. Why?

Hi,

   I'm sure I'm missing something, but I can't see it.

   Given this DD:

XXFILEOUT   DD DSN=&PDSN..PGSTRIP.UA.MFDE0S0G,

XX             DISP=(,CATLG,DELETE),

XX             UNIT=SYSDA,DATACLAS=&SMS,

XX             DCB=(RECFM=UA,BLKSIZE=182)

IEFC653I SUBSTITUTION JCL -
DSN=OFD.CHECKS.SFSIDVIN.SUN.PGSTRIP.UA.MFDE0S0G,DISP=(,CATLG,DELETE),UNI
T=SYSDA,
DATACLAS=DCSTAND,DCB=(RECFM=UA,BLKSIZE=182)     

   And this DATACLAS Definition:

Data Class Name : DCSTAND                            
                                                     
Description : STANDARD DATACLAS FOR MOST ALLOCATIONS 
              NON-EXTENDED / NON-COMPRESSED          
Recfm  . . . . . . . . . :                           
Lrecl  . . . . . . . . . :                           
Space Avgrec . . . . . . : M                         
      Avg Value  . . . . :                           
      Primary  . . . . . : 1000                      
      Secondary  . . . . : 500                       
      Directory  . . . . :                           
Retpd Or Expdt . . . . . :                           
Volume Count . . . . . . : 1                         
Add'l Volume Amount  . . :                           
Data Set Name Type  . . . . . :     
  If Extended . . . . . . . . :     
  Extended Addressability . . : NO  
  Record Access Bias  . . . . :     
Space Constraint Relief . . . : YES 
  Reduce Space Up To (%)  . . : 50  
  Dynamic Volume Count  . . . : 25  
Compaction  . . . . . . . . . : NO  
Spanned / Nonspanned  . . . . :     

  I'm seeing this:

IEF344I POP2D465 P020 STEP020 FILEOUT - ALLOCATION FAILED DUE TO DATA
FACILITY SYSTEM ERROR 
IGD17051I ALLOCATION FAILED FOR DATA SET

OFD.CHECKS.SFSIDVIN.SUN.PGSTRIP.UA.MFDE0S0G

, PRIMARY SPACE EXCEEDS 65535 TRKS


   I don't get it.  1000MB is 1GB, which is well under 65536 tracks
(4369 cylinders).  The actual file is under 100 cylinders.

   Any ideas?


Thanks,

Bob Lester 
Systems & Storage 
Oppenheimerfunds 
303.768.3504 
[email protected] 



------------------------------------------------------------------------
------
This e-mail transmission may contain information that is proprietary,
privileged and/or confidential and is intended exclusively for the
person(s) to whom it is addressed. Any use, copying, retention or
disclosure by any person other than the intended recipient or the
intended recipient's designees is strictly prohibited. If you are not
the intended recipient or their designee, please notify the sender
immediately by return e-mail and delete all copies. OppenheimerFunds
may, at its sole discretion, monitor, review, retain and/or disclose the
content of all email communications. 
========================================================================
======

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to