Is there any way to transfer an xml file to the
mainframe and keep the look of it. By default it
wraps the entire file into large records.


I want this

  EDIT       P08145.XML1                                     Columns 00001 
00072 
 Command ===>                                                  Scroll ===> PAGE 
 ****** ***************************** Top of Data ******************************
 000001   <?XML VERSION="1.0" STANDALONE="YES" ?>                               
 000002  - <DATAPACKET VERSION="2.0">                                           
 000003  - <METADATA>                                                           
 000004  - <FIELDS>                                                             
 000005    <FIELD ATTRNAME="LOCN_ID" FIELDTYPE="I4" />                          
 000006    <FIELD ATTRNAME="SERIAL_NUM" FIELDTYPE="STRING" WIDTH="12" />        
 000007    <FIELD ATTRNAME="POSITION" FIELDTYPE="I2" />                         
 000008    <FIELD ATTRNAME="GROUP" FIELDTYPE="I2" />                            
 000009    <FIELD ATTRNAME="CHANNEL" FIELDTYPE="STRING" WIDTH="2" />            
 000010    <FIELD ATTRNAME="SOURCE" FIELDTYPE="STRING" WIDTH="32" />            
 000011    <FIELD ATTRNAME="STARTED" FIELDTYPE="DATETIME" />                    
 ****** **************************** Bottom of Data ****************************

But after transfer I get this


 BROWSE    P08145.XML2                                Line 00000000 Col 001 080 
 Command ===>                                                  Scroll ===> PAGE 
********************************* Top of Data **********************************
<?xml version="1.0" standalone="yes"?>  <DATAPACKET Version="2.0"><METADATA><FIE
" fieldtype="i2"/><FIELD attrname="CHANNEL" fieldtype="string" WIDTH="2"/><FIELD
ldtype="i2"/><FIELD attrname="CONTENT" fieldtype="i2"/><FIELD attrname="UTC_BIAS
rname="INDEX" fieldtype="i2"/><FIELD attrname="RAW_VALUE" fieldtype="i4"/></FIEL
D attrname="INDEX" fieldtype="i2"/><FIELD attrname="VALUE" fieldtype="r8"/></FIE
ELD attrname="VALUE" fieldtype="r8"/></FIELDS><PARAMS/></FIELD><FIELD attrname="
IELD attrname="EVENTDETAIL" fieldtype="nested"><FIELDS><FIELD attrname="TIME_STA
"nested"><FIELDS><FIELD attrname="TIME_STAMP" fieldtype="dateTime"/><FIELD attrn
><FIELD attrname="POSITION" fieldtype="i2"/><FIELD attrname="TIME_STAMP" fieldty
N_ID="6420005" SERIAL_NUM="06420005" POSITION="10" GROUP="1" CHANNEL="M" SOURCE=
ON="1" INDEX="1" RAW_VALUE="6012089"/><ROWCONFIG POSITION="1" INDEX="2" 
RAW_VALU                

Tim Brown
Systems Specialist - Project Leader
Central Hudson Gas & Electric
284 South Ave
Poughkeepsie, NY 12601
Email: tbr...@cenhud.com <mailto:tbr...@cenhud.com> 
Phone: 845-486-5643
Fax: 845-486-5921
Cell: 845-235-4255 


This message contains confidential information and is only for the intended 
recipient.  If the reader of this message is not the intended recipient, or an 
employee or agent responsible for delivering this message to the intended 
recipient, please notify the sender immediately by replying to this note and 
deleting all copies and attachments.  Thank you. 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to