Thanks to all who replied. The RECYCLE stopped after I canceled one TCB. I will include the PATCH as provided by Dave O'Brien.
Unfortunately to muddy my waters a bit, I also had a drive go bad that held the tape that recycle wanted. Don't you just love hardware? ;-D Lizette -----Original Message----- >From: "Adams, Rick" <rick.ad...@fmr.com> >Sent: Jun 15, 2010 1:36 PM >To: IBM-MAIN@bama.ua.edu >Subject: Re: How to terminate a RECYCLE on DFHSM > >Lizette, >You can issue a QUERY ACT(TCBADDRESS) and identify the TCB of the recycle >process. Then you can cancel the TCB by issuing C TCBADDRESS(x'yyyyyyyyy') >with yyyyyyyy being the TCBADDRESS identified in the quesry command. IBM >recommends that you hold the process prior to issuing the cancel. I usually >only use this process when I have a hung task - but it will kill the active >task. > >Thanks....Rick > >-----Original Message----- >From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of >Lizette Koehler >Sent: Tuesday, June 15, 2010 10:28 AM >To: IBM-MAIN@bama.ua.edu >Subject: Re: How to terminate a RECYCLE on DFHSM > >David, > >So I can have recall and recycle run at the same time with these patches? >Great. > >How about terminating my current HSM Recycle. > >Lizette > > >-----Original Message----- >>From: "O'Brien, David (NIH/CIT) [C]" <obrie...@mail.nih.gov> >>Sent: Jun 15, 2010 11:24 AM >>To: IBM-MAIN@bama.ua.edu >>Subject: Re: How to terminate a RECYCLE on DFHSM >> >>Lizette, >> >> The following is valid for Zos 1.9 >> >> /* ALLOW RECALL TO ACCESS TAPES ASSIGNED TO RECYCLE OR TAPECOPY >> /******************************************************************** >> PATCH .MCVT.+315 X'05' >> PATCH .MCVT.+53 BITS(.....1..) >> >>Thank You, >>Dave O'Brien >>NIH Contractor >>________________________________________ >>From: Lizette Koehler [stars...@mindspring.com] >>Sent: Tuesday, June 15, 2010 11:14 AM >>To: IBM-MAIN@bama.ua.edu >>Subject: How to terminate a RECYCLE on DFHSM >> >>I started a recycle and now need to stop it. I issue the F DFHSM,HOLD >>RECYCLE but a display says HELD ACTIVE. >> >>When will it go inactive? At the end of the task/volume/?? >> >>Does RECYCLE hold up my RECALL tasks on DFHSM. >> >>Lizette ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html