>I got the following message running TSO in batch using the receive command
>
>
>
>My question doing a receive command what does SYS00006 Look for
>
>
>
>IEF877E IBMUSER$ NEEDS 1 UNIT(S)  925
>
>FOR RECEIVE SYS00006
>
>FOR VOLUME SCRTCH-   1
>
>

Default unit for the TSO user?  Did you try specifying an output data set
name?  Is the output dsn SMS controlled?  If not is receive trying to go to
a public / storage mounted volume and none exist in your environment.

Try RECEIVE and specify the the output data set name, UNIT(SYSALLDA) and
a volser.

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS       
mailto:mzel...@flash.net                                          
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html 