Mark Zelden wrote:
On Fri, 20 Aug 2010 12:51:42 -0600, Steve Comstock
<[email protected]> wrote:
Now that the z196 provides us with a CEC with up to 80
processors, and since a Parallel Sysplex can include
up to 32 systems, does that mean that Parallel Sysplex
now supports 32 x 80 = 2560 active CPs, or are we still
software bound to 2048 CPs per Parallel Sysplex?
No. 64 CPs (any mixture of the various types, GP, zAAP & zIIP) is still
the limit per LPAR. So 2048 is the limit.
Ah. Thanks, Mark.