He could also check out the VVDSFIX program which is available for download
from IBM.  I've used it to correct some catalog inconsistencies which seem
familiar to what the OP has encountered.

On Wed, 5 Jan 2011 12:10:50 -0600, Tom Marchant <m42tom-ibmm...@yahoo.com>
wrote:

>On Wed, 5 Jan 2011 12:54:51 -0500, Mark Pace wrote:
>
>> DELETE SYS1.VVDS.VSTD001 CATALOG(CATALOG.USER.SYSTEM.ZOS19) -
>>     NOSCRATCH FILE(DD1)
>>IDC3012I ENTRY SYS1.VVDS.VSTD001 NOT FOUND
>
>There is no entry in the BCS for the VVDS.  You would first need to catalog
>the VVDS in that catalog.  Then you should be able to do the DELETE NOSCRATCH
>
>--
>Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to