>From context, I suppose SA means System Automation.

You can use PARMLIB's MPFLST to call a program on receipt of the RMF 
initialization complete message (ERB100I); the program calls SVC34 to issue the 
S RMFGAT command (or whatever). The program can be generalized for other system 
automation since the message it triggers on is available to the program.

In a previous barebones (z/OS 1.8. 1.9) site I used the venerable OTTO from 
file 332 of the CBT tape quite successfully. File 623 might be more functional, 
but I can't personally vouch for that one. 

Ant.
Northern Territory Govt., Australia 

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
ibmnew
Sent: Thursday, 7 April 2011 11:54 AM
To: IBM-MAIN@bama.ua.edu
Subject: How to start RMF Monitor III automatically after IPL the system.

Hi all 

 We don't have SA. 

 How to start RMF Monitor III automatically after IPL the system?

Any suggestions is apprecited!

Thanks a lot!

Jason Cai

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to