John, 
 See Hiper Fixes document 081904/111204A on the IBM Service Link website.  
There are specific conditions when the error may occur that are described in 
these two documents.

Regards,
Steve

Service Link website: 
https://app-06.www.ibm.com/servers/resourcelink/hom03010.nsf?OpenDatabase&login_


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED]
Behalf Of McKown, John
Sent: Monday, December 05, 2005 8:50 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: z890 question - dynamic activate


I don't think it was here mentioned here (could be wrong), but I have a
vague memory of somebody telling me that there is a possibility of an
outage if a hardware ACTIVATE is done on a z890. Something about a bug
in a specific LIC level? Does anybody else remember such a thing?

--
John McKown