--------------------------------<snip>------------------------------

Barry,

The STORAGE GROUP was backed up via HSM, what I didn't say correctly that the 
volume was not backed up (full dump).
When I am able to do a browse of the dsn, all the members are displayed 
correctly, however when I browse each member I get the following :

I/O error
When I press F1 for more info I get the following:
An I/O error was encountered reading the first record requested.

The DCB of the PDS is as follows, however I cannot be sure if it is correct 
since this PDS was inherited from a client

Organization . . . : PO Record format . . . : FBA Record length . . . : 133 Block size . . . . : 133 1st extent cylinders: 5 Secondary cylinders : 2 Data set name type : PDS
----------------------------------<unsnip>-----------------------------------
This looks very much like some program had its SYSPRINT directed to a member of this PDS, altering the DCB attributes in the process. You'll just have to experiment to find the correct attributes, but I'd find the one member that's readable and move it out to another dataset of FBA/133 format and delete it from this *altered* PDS before doing anything. I think that as a starting point, I'd try a BLKSIZE that's as close to a half-track as I could get with this same lrecl value.

Rick

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to