I believe there is a delinker on the CBT tape. May be easier to parse that and insert a NAME card after every END card.
On Fri, 9 Sep 2011 12:11:37 +0200 Thomas Berg <thomas.b...@swedbank.se> wrote: :>> -----Ursprungligt meddelande----- :>> Från: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] För :>> Binyamin Dissen :>> Skickat: den 9 september 2011 12:06 :>> Till: IBM-MAIN@bama.ua.edu :>> Ämne: Re: How to "splitting" loadmudules :>> :>> On Fri, 9 Sep 2011 11:49:28 +0200 Thomas Berg <thomas.b...@swedbank.se> :>> wrote: :>> :>> :>> -----Ursprungligt meddelande----- :>> :>> Från: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] För :>> :>> Miklos Szigetvari :>> :>> Skickat: den 9 september 2011 10:54 :>> :>> Till: IBM-MAIN@bama.ua.edu :>> :>> Ämne: Re: How to "splitting" loadmudules :>> :>> :>> :>> On 9/9/2011 9:39 AM, Thomas Berg wrote: :>> :>> > I have a need to "split" loadmodules into separate modules. :>> :>> > E g: a load module, A, is consisting of three submodules, A, B and :>> C. I :>> :>> want to split it into three separate modules into a loadlibrary. :>> :>> > Is there a more convenient way to do this other than generate :>> REPLACE :>> :>> cards for the BINDER and - in this example - run it three times. :>> :>> > (Other than writing an assembler program using IEW macros.) :>> :>> > :>> :>> > I have to do this for several thousands of load modules. :>> :>> > :>> :>> > :>> :>> > :>> :>> > Regards, :>> :>> > Thomas Berg :>> :>> > _________________________________________ :>> :>> > Thomas Berg Specialist A M SWEDBANK :>> :>> > :>> :>> > :>> :>> > -------------------------------------------------------------------- :>> -- :>> :>> > For IBM-MAIN subscribe / signoff / archive access instructions, :>> :>> > send email to lists...@bama.ua.edu with the message: GET IBM-MAIN :>> INFO :>> :>> > Search the archives at http://bama.ua.edu/archives/ibm-main.html :>> :>> > :>> :>> > :>> :>> Why do you need this ? :>> :> :>> :>We are trying to use IBM's BIND MANAGER to get rid of unused packages in :>> DB2. :>> :>But it takes something like 24 hours to run on one DB2 system. And this :>> is almost totally depending on the amount of loadmodules it have to work :>> with. :>> :>So I'm trying to reduce that. :>> :>> One would think that splitting them would increase the number of load :>> modules. :> :>There's a LOT of duplicates of submodules. And it reads all CSECTs. :> :> :> :>Regards, :>Thomas Berg :>_________________________________________ :>Thomas Berg Specialist A M SWEDBANK :> :>---------------------------------------------------------------------- :>For IBM-MAIN subscribe / signoff / archive access instructions, :>send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO :>Search the archives at http://bama.ua.edu/archives/ibm-main.html -- Binyamin Dissen <bdis...@dissensoftware.com> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel Should you use the mailblocks package and expect a response from me, you should preauthorize the dissensoftware.com domain. I very rarely bother responding to challenge/response systems, especially those from irresponsible companies. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html