I have already a routine that lists the csects and generate the REPLACE's. 
It works but I was wondering if there was another way that e g was faster etc. 
(I have a rexx that reads the loadlibs and "splits" the submodules into a 
multiple of target loadlibs.) 
As this - if it's maintainable etc. - will be put in production are stability 
and time important factors. 


 
Regards, 
Thomas Berg 
_________________________________________ 
Thomas Berg   Specialist   A M   SWEDBANK 


> -----Ursprungligt meddelande-----
> Från: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] För
> McKown, John
> Skickat: den 9 september 2011 14:43
> Till: IBM-MAIN@bama.ua.edu
> Ämne: Re: How to "splitting" loadmodules
> 
> I usually agree. But I then get "dinged" because I just answer the
> question instead of addressing the need. IOW, you can't win sometimes.
> 
> Why not run AMBLIST to list the names of the CSECTs. Then run REXX against
> that to create the Binder control cards to split the load module?
> 
> --
> John McKown
> Systems Engineer IV
> IT
> 
> Administrative Services Group
> 
> HealthMarkets(r)
> 
> 9151 Boulevard 26 * N. Richland Hills * TX 76010
> (817) 255-3225 phone *
> john.mck...@healthmarkets.com * www.HealthMarkets.com
> 
> Confidentiality Notice: This e-mail message may contain confidential or
> proprietary information. If you are not the intended recipient, please
> contact the sender by reply e-mail and destroy all copies of the original
> message. HealthMarkets(r) is the brand name for products underwritten and
> issued by the insurance subsidiaries of HealthMarkets, Inc. -The
> Chesapeake Life Insurance Company(r), Mid-West National Life Insurance
> Company of TennesseeSM and The MEGA Life and Health Insurance Company.SM
> 
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List
> > [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of zMan
> > Sent: Friday, September 09, 2011 7:27 AM
> > To: IBM-MAIN@bama.ua.edu
> > Subject: Re: SV: SV: SV: How to "splitting" loadmudules
> >
> > On Fri, Sep 9, 2011 at 8:19 AM, Thomas Berg
> > <thomas.b...@swedbank.se> wrote:
> > > I'm not going to RUN these "delinked" modules!
> > > They are just for the BIND MANAGER to read and search for
> > whatever (contoken I assume).
> > > (They are just "indata" here.)
> >
> > Howzabout folks stop telling him he doesn't want to do what he clearly
> > *does* want to do, and try to answer his question? Y'all sound like a
> > bunch of UNIX weenies. Sheesh.
> > --
> > zMan -- "I've got a mainframe and I'm not afraid to use it"
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
> > Search the archives at http://bama.ua.edu/archives/ibm-main.html
> >
> >
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to