Well, well, well....I was *sure* that this could not be done.  Wrong.

After a closer reading of the SMP/E Commands manual, it appears that SMP/E
fully supports sending ++HOLD ACTION or ++HOLD EC statements "after the
fact" via the same mechanism (RECEIVE HOLDDATA) as ++HOLD ERROR commands.

So, the answer appears to be "yes", IBM could send electronic updates to
++HOLD information.  Today they do not do this, but SMP/E itself apparently
supports this.

For those interested in looking into this further, in the SMP/E manuals,
they uses the phrase "HOLDSYSTEM (external)" to refer to ++HOLD SYSTEM
statements which are provided to a global zone via a RECEIVE HOLDDATA
command and the SMPHOLD DD statement, and the phrase "HOLDSYSTEM
(internal)" to refer to ++HOLD SYSTEM statements which are included as part
of a PTF and provided to a global zone via a RECEIVE SYSMODS command and
the SMPPTFIN DD statement.

Brian

On Fri, 30 Dec 2005 12:32:54 -0500, Shmuel Metz (Seymour J.) <shmuel+ibm-
[EMAIL PROTECTED]> wrote:

>In <[EMAIL PROTECTED]>, on 12/29/2005
>   at 02:46 PM, Brian Peterson <[EMAIL PROTECTED]>
>said:
>
>>What is really needed is a ++HOLD ACTION or ++HOLD EC with text
>>stating that "Vendor-A microcode level xxx is required for
>>compatability with PTF UZ11111".  However, ++HOLD ACTION / ++HOLD EC
>>text must be included in the original PTF - they cannot be added
>>later.
>
>Are you sure they can't be picked up by RECEIVE HOLDDATA?
>
>--
>     Shmuel (Seymour J.) Metz, SysProg and JOAT

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,