Hello,
Problem resolved after adding ASMPRINT . Thanks all of you to
help me .
Regards
Saurabh
On Tue, Jan 3, 2012 at 4:20 PM, saurabh khandelwal <
[email protected]> wrote:
> I dont have SMMPRINT DD NAMe defined in my SMPE . I will add this DDNAME
> in my SYSLIB DDDEF in target zone.
>
> Also I check for ASMA90 utility. I already have this option specified.
>
> DEFINITION - UTILITY ENTRY ASMA90
> ===>
>
> Verify or enter operands for UTILITY entry ASMA90:
>
> LOAD MODULE NAME ===> ASMA90 (Name of load module
> invoked for this utility)
>
> HIGHEST RETURN CODE ===> 0 (Value between 0 and 16)
> The highest return code to
> be considered successful.
> Note: Value may be overridden
> by LMOD Return Code subentry
> PRINT DD NAME ===> SYSPRINT (Name of PRINT DD
> statement to be used)
> PARM ===> XREF(SHORT),DECK,NOOBJECT,*GOFF,LIST(133)*
> ,OPTABLE(U
> ===> NI)
> (Parameter string passed to load
> module, up to 100 characters)
>
> LIST MEMBER NAMES ===> (List member names when copying)
> YES(Y), or NO(N). Default is YES.
>
>
> Regards
>
>
>
> On Mon, Jan 2, 2012 at 9:49 PM, Kurt Quackenbush <[email protected]> wrote:
>
>> This issue is due to ASMPRINT missing.
>>>
>>> ** ASMA429W SYSPRINT LRECL should be at least 133 when GOFF/XOBJECT
>>> option
>>> is specified
>>>
>>
>> Missing, or just defined poorly? You can try to add the following
>> assembler parameters to the active UTILITY entry:
>>
>> GOFF,LIST(133)
>>
>> Kurt Quackenbush -- IBM, SMP/E Development
>>
>>
>> ------------------------------**------------------------------**
>> ----------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
>>
>
>
>
> --
> Thanks & Regards
> Saurabh Khandelwal
>
--
Thanks & Regards
Saurabh Khandelwal
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN