On Fri, 6 Jan 2012 13:04:59 -0600 Donald Likens <dlik...@infosecinc.com>
wrote:

:>I am getting the following Abend:

:>IEA995I SYMPTOM DUMP OUTPUT  172                   
:>SYSTEM COMPLETION CODE=72A  REASON CODE=00000010   
:> TIME=10.15.04  SEQ=01338  CPU=0000  ASID=0042     

:>The book states:

:>Explanation: During processing for an ATTACH
:>macro, the system encountered an error.
:>Register 15 contains a hexadecimal reason code that
:>explains the error:

:>10 A caller using the ATTACHX macro
:>encountered nonzero access list entry tokens
:>(ALETs). The ALETs should have been set to
:>zero, but they were not.

:>I do not understand what the book is taking about. My attachx follows:

:>ATTACHX EPLOC=MEASTSMN,ETXR=TSMNDOWN,PARAM=(TSMNWKSA) 

:>I do not see tokens involved with ATTACHX.

:>Can someone please explain what IBM is talking about?

My guess is that you are in AR mode and the AR15 is non-zero.

Always issue SYSSTATE ASCENV=AR when in AR mode so that system macros generate
correct code.

--
Binyamin Dissen <bdis...@dissensoftware.com>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,