On 6 Jun 2012 07:04:52 -0700, in bit.listserv.ibm-main you wrote:

>John,
>
>I fixed it, but the fix was odd, I added a //sysout dd sysout=* 
>It now works

If the statement //SYSOUT DD some parameters is missing and you have a
DISPLAY something in your program and the LE runtime option CBLQDA is
(ON), the program will dynamically allocate a temporary file with
DISP=(NEW,DELETE) and write to it.  This is true for all QSAM files.
If the LE option is CBLQDA(OFF), you will get an abend on OPEN (or for
DISPLAY, first write).  CBLQDA(ON) is purportedly to conform to the
COBOL standard although the standard assumed that the file would
remain somewhere.

Clark Morris  
>
>Scott ford
>www.identityforge.com
>
>On Jun 6, 2012, at 9:16 AM, "McKown, John" <john.mck...@healthmarkets.com> 
>wrote:
>
>> Did somebody change the LE options? That's all that I can think of. No, I 
>> don't know what the option(s) might be that could cause this difference. 
>> 
>> -- 
>> John McKown 
>> Systems Engineer IV
>> IT
>> 
>> Administrative Services Group
>> 
>> HealthMarkets(r)
>> 
>> 9151 Boulevard 26 * N. Richland Hills * TX 76010
>> (817) 255-3225 phone * 
>> john.mck...@healthmarkets.com * www.HealthMarkets.com
>> 
>> Confidentiality Notice: This e-mail message may contain confidential or 
>> proprietary information. If you are not the intended recipient, please 
>> contact the sender by reply e-mail and destroy all copies of the original 
>> message. HealthMarkets(r) is the brand name for products underwritten and 
>> issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake 
>> Life Insurance Company(r), Mid-West National Life Insurance Company of 
>> TennesseeSM and The MEGA Life and Health Insurance Company.SM
>> 
>>> -----Original Message-----
>>> From: IBM Mainframe Discussion List 
>>> [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Scott Ford
>>> Sent: Wednesday, June 06, 2012 8:03 AM
>>> To: IBM-MAIN@bama.ua.edu
>>> Subject: Re: LE COBOL odd behavior
>>> 
>>> I should have added under z/os1.11 works fine
>>> 
>>> Scott ford
>>> www.identityforge.com
>>> 
>>> On Jun 5, 2012, at 11:09 PM, Scott Ford 
>>> <scott_j_f...@yahoo.com> wrote:
>>> 
>>>> All,
>>>> 
>>>> We migrated to z/os 1.12 , LE COBOL. I have noticed on a 
>>> COBOL program running as a STC,
>>>> No yucks please, a Display or Write to Sysprint takes a 
>>> long time , in one case I cancelled a STC and the output was 
>>> in sysprint, but under ISPs, sdf , not there at all. Is this 
>>> a bug or a new parm in Maybe z/os , guessing ..?
>>>> 
>>>> Scott ford
>>>> www.identityforge.com
>>>> 
>>>> 
>>> ----------------------------------------------------------------------
>>>> For IBM-MAIN subscribe / signoff / archive access instructions,
>>>> send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN
>>> 
>>> ----------------------------------------------------------------------
>>> For IBM-MAIN subscribe / signoff / archive access instructions,
>>> send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN
>>> 
>>> 
>> 
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN