Oswaldo,

Using CPVOLUME in the copy command requires the source and
target volumes to be in VM format.
You will need to have the target volume initialized at a VM system
or use ICKDSF to initialize the target volume with a
VTOC starting on track zero, record five.

Hope this helps.....

..............snip ..............
I'm trying to use DFDSS under  z/OS 1.4 to copy my z/VM 51 volumes and  I
am
getting the
following error message for every volume:
ADR307E (001)-OPNCL(11), UNABLE TO OPEN VOLUME HI8801, 16
>From message guide :
16
             The VM-formatted volume does not have an OS-compatible VTOC
beginning on track zero, record five.
I try to format from z/OS, but without success with the copy, but when I
format the output volumes under z/VM (ICKDSF CPVOLUME)
its is OK.
I am using the sysin :
COPY    TRACKS(0,0,3338,14)  COPYVOLID -
        ADMINISTRATOR  PURGE -
        CPVOLUME -
        INDDNAME(ENTRADA) -
        OUTDDNAME(SAIDA)

Is it the only way to copy the volumes :
1) Format the volume from z/VM
2) Copy using DFDSS from z/OS
or maybe I can format by z/OS ?
Thanks.
Oswaldo
............................ snip ......................
_________________________________________________________________________
Paolo Cacciari
Business Continuity and Recovery Services, IBM Global Services - South
Region, EMEA
Via Darwin 85, 20019 Settimo Milanese(MI) – Italy - MISET001
"The goal is to be prepared for a disaster not to continually plan for a
successful test"
* [EMAIL PROTECTED]
( + 39 051 41.36799   Mobile: + 39 335 6287584
7 + 39 02 596.23288

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html