Sorry I haven't had a chance to respond you your assistance and replies, 
but there was more pressing business that required my attention.   I'm 
presently rounding up all the pieces that I can find that make up the load 
module.  I have secured the Enterprise COBOL manuals.  I checked linklst 
and it contains no COBOL2 load libraries. I am including a portion of the 
ABEND-AID dump that was produced.  I hope to have more information and 
questions in the near future.

Thank you for your assistance,

David


Abend-Aid piece:

 The IBM message that corresponds to the condition is: 
0CEE3204S The system detected a protection exception (System 
          Completion Code=0C4). 
 
 
 
 
 
 
 ******************************************* 
 *             Error Location              * 
 ******************************************* 
0The next sequential instruction to be executed in program OFDBINIT was 
 at displacement 00001C74. 
0The program was compiled on 22 MAR 2006 and is 00006AC8 bytes long. 
0It is part of load module DBINIT. 
0The module was loaded from JOBLIB library 
 TDM692.PRIVATE.CORE.R122005.LOADLIBB.                              
0The module was link edited on 24 MAR 2006 and is 00021668 bytes long. 
0The last known I/O request or call in the program above was issued with 
 a return address at displacement 00001C62. 
 
 
 ******************************************* 
 *           Call Trace Summary            * 
1                          A B E N D - A I D                    PAGE   3 
0******************************************* 
 
 *******Calling*******  ****Return****           *******Called******** 
 Load-Mod  Program      Type     Value           Program      Load-Mod 
 
 *SYSTEM                                Links to BLB3050      BLB3050 
 
 BLB3050   BLB3050                      Calls    CEEBTOR      CEEBINIT 
 
CEEBINIT  CEEBTOR                      Calls    BLB3050      BLB3050 
 
BLB3050   BLB3050      DISP  0000083E  Calls    INITOFFL     BLB3050 
 
BLB3050   INITOFFL     DISP  00001916  Calls    DBIO         BLB3050 
 
BLB3050   DBIO         DISP  00000BFE  Calls    IGZCFCC      IGZCPAC 
 
IGZCPAC   IGZCFCC      DISP  00000320  Calls    IGZCD24      IGZCD24 
 
IGZCD24   IGZCD24      DISP  0000006A  Calls    DBINIT       DBINIT 
 
DBINIT    DBINIT       DISP  000000C4  Calls    OFDBINIT     DBINIT   *
 
DBINIT    OFDBINIT     DISP  00001C62  Calls    DBFILEIO     DBINIT 
 
DBINIT    DBFILEIO                     Calls                 CEEPLPKA 
 
CEEPLPKA               DISP  048300B6  Calls    LEAID        LEAID 
 
 LEAID     LEAID        DISP  00000ADC  Calls    SNAPAID      LEAID 
 
                                               Program Causing Error  * 
0One or more modules loaded from the LINKLIST. 
 Current LINKLIST library set is LNKLST00 
 
 
 ----------------------------------------------------------------------- 
 Load-Mod    Amode  Rmode  Resides in 
 
 DBINIT       24     24    TDM692.PRIVATE.CORE.R122005.LOADLIBB 
 BLB3050      24     24    TEC414.TLR.COBOL.LOAD 
 CEEBINIT     24     24    CEE.SCEERUN 
 IGZCPAC      31    ANY    CEE.SCEERUN 
 IGZCD24      31     24    CEE.SCEERUN 
 CEEPLPKA     31    ANY    EPLPA 
 LEAID        31    ANY    SYS3.AA.R090500.SPAALOAD 
 ----------------------------------------------------------------------- 
 
 
 ******************************************* 
 *     Application Program Attributes      * 
 ******************************************* 
1                          A B E N D - A I D                    PAGE   4 
0 
 Load-Mod  Program       Compile Date  Length    Language 
 
 BLB3050   BLB3050       06 APR 2006   00008F9F  COBOL Z/OS V3R3M1 
 
 BLB3050   INITOFFL      24 MAR 2006   000039FC  COBOL Z/OS V3R3M1 
 
 BLB3050   DBIO          24 MAR 2006   00001074  COBOL Z/OS V3R3M1 
 
 DBINIT    DBINIT        22 MAR 2006   00001ADE  HLASM 
  
 DBINIT    OFDBINIT      22 MAR 2006   00006AC8  COBOL Z/OS V3R3M1 
 
 DBINIT    DBFILEIO      22 MAR 2006   00002001  HLASM 
 
 
 ******************************************* 
 *      Supporting Environmental Data      * 
 ******************************************* 
 
  Abend PSW - 078D0000 000920EC   A(OFDBINIT) + 00001C74 
  Prog PSW  - 078D0000 000920EC   A(OFDBINIT) + 00001C74 
  Load Module - DBINIT                    Entry Point Address - 0008E998 
  ILC - 06,   INTC - 04                   Load  Point Address - 0008E998 
   Registers at time of error  (Descriptions based on 24 bit addresses) 
0REG HEX       Decimal         Description 
 R0  0005E528         386,344  A(0003C000) + 00022528, PVT SP=001 ALLOC 
 R1  0003E2F8         254,712  A(0003C000) + 000022F8, PVT SP=001 ALLOC 
 R2  000B50B8         741,560  A(000B0000) + 000050B8, PVT SP=002 ALLOC 
 R3  00E34040      14,893,120  A(ISPSUBX ) + 00001040 
 R4  000B0038         720,952  A(000B0000) + 00000038, PVT SP=002 ALLOC 
 R5  0000F738          63,288  A(BLB3050 ) + 000079A8 
 R6  00000000               0 
 R7  00063200         406,016  A(00063000) + 00000200, PVT SP=002 ALLOC 
 R8  000905C8         591,304  A(OFDBINIT) + 00000150 
 R9  0005E360         385,888  A(0003C000) + 00022360, PVT SP=001 ALLOC 
 R10 000B00B8         721,080  A(000B0000) + 000000B8, PVT SP=002 ALLOC 
 R11 00091D6A         597,354  A(OFDBINIT) + 000018F2 
 R12 00090574         591,220  A(OFDBINIT) + 000000FC 
 R13 0003DBA0         252,832  A(0003C000) + 00001BA0, PVT SP=001 ALLOC 
 R14 500920DA   1,342,775,514  A(OFDBINIT) + 00001C62 
 R15 00000000               0 

 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
 

Reply via email to