Hi All,

Is VTAM recycle required when the ISTMNPS structure is changed?

I understand from the Redbooks that its is not.
VTAM is supposed to automatically detect the changes.
If needed we could do 'V NET,CFS,ACTION=CONNECT,STRNAME=ISTMNPS'.

While VTAM started for the first time it had the following error:
IXL013I IXLCONN REQUEST FOR STRUCTURE ISTMNPS FAILED.  
IST1365I FSNCN CONNECTION ATTEMPT TO STRUCTURE ISTMNPS FAILED
IST1366I FSNCN MVS MACRO IXLCONN FAILED - RTN CODE= 0C - REAS
IXLCONN RETURN CODE: 0000000C,  REASON CODE: 02010C08        
        CONADIAG0:   00000002
        CONADIAG1:   00000008
        CONADIAG2:   00000C08
IXL015I STRUCTURE ALLOCATION INFORMATION FOR  
STRUCTURE ISTMNPS, CONNECTOR NAME NETB_CDRMDOS
CFNAME     ALLOCATION STATUS/FAILURE REASON
--------   ---------------------------------
ICF11      INVALID STRUCTURE SIZE
ICF21      INVALID STRUCTURE SIZE 

I then increased the INITSIZE and SIZE. 

In my environment a VTAM recycle(IPL) alone made VTAM aware of the ISTMNPS 
structure change.

Regards,
Anu

----------------------------------------------------------------------