On Thu, 26 Oct 2006 15:09:23 EDT, Ed Finnell <[EMAIL PROTECTED]> wrote:

>
>In a message dated 10/26/2006 1:27:55 P.M. Central Standard Time,
>[EMAIL PROTECTED] writes:
>
>The job  is only one step.  I have the Time parm specified on the EXEC only.
> I will code the time parm in the job card as well.  Regarding exits I
>wouldn't know how to find that out.
>
>
>
>>>
>Look at the time used in the flower box and do a BXLE to see if it's  greater
>than or less than the time on the STEP time?
>

Flower boxes are a local thing from IEFACTRT SMF exits.  Not all systems
have them.   But they all do have IEF374I / IEF376I if the proper
MSGLEVEL is used.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - GITO
mailto:[EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to