This daybreak the problem was fixed. The HD failure on the primary SE 
occurred during the daily mirror process to the alternate SE. This caused 
an incomplete data mirror to the alternate that prevent the boot 
completion on the alternate (that occurs when the SE assume its primary 
role).

After the hardware fix the primary SE was reinstalled from the original 
code and upgraded using the backup from HMC (that has all the microcode 
update and user data). The alternate SE was reinstalled also and after 
that all the communications where reestablished normally.

This maintenance was completely transparent to the LPARs and no power on 
was required. 

----------------------------------------------------------------------