John,

Take a look at your SMS rules, what DATACLAS is being assigned to these
tapes; and what media-type is that DATACLAS supposed to use. Sounds like
your SMS rules are directing the allocation to MEDIA3 cartridges.

Russell Witt
CA-1 Level-2 Support Manager

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED]
Behalf Of John Benik
Sent: Friday, December 22, 2006 12:13 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Trying to switch from 3590J to 3590K tapes.


We are attempting to switch from 3590J(MEDIA3) to 3590K(media4) tapes but
HSM is issuing the messages below.  We have ejected all the J media
scratches and inserted enough of the K media to at least get through
tonight.  But it's critical that we figure this out before this weekend.
CBR4195I LACS retry possible for job HSMS1:  422
IEE763I NAME= CBRLLACS CODE= 140169
CBR4000I LACS MOUNT permanent error for drive 1242.
CBR4105I No MEDIA3 scratch volumes available in library
IEE764I END OF CBR4195I   RELATED MESSAGES

Does anybody know if there is additional work to be done to start using
the K tapes, as we were told it was a simple switch?  It was very simple
to switch to K tapes for the backend of a VTS.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to